Research Article

Fault Diagnosis of Beam-Like Structure Using Modified Fuzzy Technique

Table 5

Measured nondimensional natural frequencies and mode shape differences of fixed-fixed beam.

Sl. numberTest pointsNondimensional natural frequencyNondimensional mode shape differences

1Uncrack0.0001.0001.0001.0000.0000.0000.000
20.1250.2000.9350.9570.9520.2620.2260.309
30.1250.3000.9240.9550.950.3780.3150.378
40.1250.4000.9090.9430.9480.1750.0340.082
50.2500.2000.9410.9620.9550.141−0.0820.189
60.2500.3000.9190.9610.9390.012−0.8050.242
70.2500.4000.9320.9570.9370.1780.0590.372
80.3750.2000.9370.950.9540.0650.2390.394
90.3750.3000.9290.9480.9510.0780.2910.376
100.3750.4000.9310.9420.949−0.0350.2960.39