Research Article

Monitoring Machines by Using a Hybrid Method Combining MED, EMD, and TKEO

Table 4

Correlation value between IMF1 (obtained by EMD and MED-EMD) and the signal when rotating at 600 rpm.

600 rpm
0 μm50 μm100 μm

EMD0.180.240.15
MED-EMD0.380.390.72