Research Article

A Highly Reliable Embedded Optical Torque Sensor Based on Flexure Spring

Table 3

Results of finite element analysis.

RibsStructureDisplacementStressResults

1Max displacement 4.0835 deg
Max stress 157.32 Mpa
2Max displacement 0.3097 deg
Max stress 65.627 Mpa
3Max displacement 0.0272 deg
Max stress 17.55 Mpa
4Max displacement 0.0134 deg
Max stress 11.767 Mpa
5Max displacement 0.0074 deg
Max stress 6.9949 Mpa
6Max displacement 0.0049 deg
Max-stress 5.8602 Mpa