Biomechanical Analysis of the Forces Exerted during Different Occlusion Conditions following Bilateral Sagittal Split Osteotomy Treatment for Mandibular Deficiency
Table 5
Maximum von Mises stress values at the screw insertion sites.
Peak von Mises stress at b1 on the mandible (MPa)
Peak von Mises stress at b2 on the mandible (MPa)
Peak von Mises stress at b3 on the mandible (MPa)
Peak von Mises stress at b4 on the mandible (MPa)
Peak von Mises stress at b5 on the mandible (MPa)
Peak von Mises stress at b6 on the mandible (MPa)
Peak von Mises stress at b7 on the mandible (MPa)
Peak von Mises stress at b8 on the mandible (MPa)
INC
20.324
39.124
29.273
15.191
26.173
25.474
39.034
20.462
ICP
66.423
126.500
102.480
43.784
52.865
86.761
125.960
66.597
RMOL
48.194
82.709
61.630
48.399
115.490
98.718
109.400
65.414
RGF
22.321
41.563
39.653
14.452
30.620
26.072
38.142
16.680