Research Article
[Retracted] Benefits of Contrast-Enhanced Ultrasonography to the Differential Diagnosis of TI-RADS 4-5 Thyroid Nodules
Table 3
Ultrasonographic characteristics of thyroid nodules (ECUS) [
].
| ECUS | | Benign () | Malignant () | | |
| Enhancement degree | Hyperenhancement | 8 (33.33) | 1 (3.03) | 23.749 | <0.001 | | Isoenhancement | 13 (54.17) | 7 (21.21) | | | | Hypoenhancement | 3 (12.50) | 24 (72.73) | | | | No enhancement | 0 (0.00) | 1 (3.03) | | | Enhanced border | Clear | 17 (70.83) | 11 (33.33) | 7.818 | 0.005 | | Partially clear or unclear | 7 (29.17) | 22 (66.67) | | | Perfusion pattern | Centripetal | 7 (29.17) | 8 (24.24) | 3.822 | 0.148 | Centrifugal | 8 (33.33) | 19 (57.58) | | | | Pleiotropic | 9 (37.50) | 6 (18.18) | | | Enhancement pattern | Homogeneous | 10 (41.67) | 6 (18.18) | 20.280 | <0.001 | | Heterogeneous | 2 (8.33) | 21 (63.64) | | | | Annular | 7 (29.17) | 1 (3.03) | | | | Nodular | 5 (20.83) | 5 (15.15) | | |
|
|