Applied Bionics and Biomechanics / 2022 / Article / Tab 1 / Research Article
Analysis of the Effectiveness of Arytenoidectomy and Posterior Cordectomy with the Use of CFD Airflow Measurements in Patients with BVFP: A Retrospective Study Table 1 Statistical results for measured parameters before and after the surgery.
Parameter Operation dependency M SD Me IQR Min Max Sk. S Before 18.67 8.49 18.04 11.27 1.2 37.73 0.14 After 41.83 15.1 38.09 21.44 18.1 86.42 0.73 FEV1 Before 1.54 0.67 1.44 1.1 0.34 2.72 0.18 After 2.07 0.66 2.02 0.91 0.55 3.44 −0.24 FVC Before 2.38 0.97 2.56 1.47 0.4 4.09 −0.29 After 2.89 0.85 2.98 1.08 1.26 4.88 0.17 PEF Before 2.47 1.15 2.08 1.57 0.88 5.55 0.93 After 3.66 1.26 3.63 1.33 0.62 6.33 −0.37 w inlet for PEF Before 5.04 2.35 4.24 3.19 1.8 11.31 0.94 After 7.45 2.57 7.4 2.72 1.26 12.9 −0.37 w max for PEF Before 185.21 107.47 162.07 134.96 50.88 460.69 1 After 126.89 62.01 122.65 78.86 37.36 341.21 1.22 PEFΔP CFD Before 46,747 81,723.3 20,109 28,906 2,195 446,989 3.85 After 14,493 15,692.8 11,713 13,392 938 86,764 3.11 w max CFD Before 7.39 7.24 4.97 3.49 2.93 42.09 3.7 After 2.94 1.14 2.88 1.36 1.38 6.06 1.05 ΔP CFD Before 170.77 711.13 26.47 40.52 6.23 4111 5.39 After 7.54 6 6.1 5.67 1.36 28.88 1.91 VAS Before 8.42 1.52 9 2 4 10 −1.02 After 3.85 2.48 4 2 1 10 1.37 MRC Before 4.3 0.77 4 1 2 5 −0.98 After 2 1.2 2 1 1 5 1.44