Research Article
Case Study of Remaining Service Life Assessment of a Cooling Water Intake Concrete Structure in Indonesia
Table 9
Corrosion initiation time and concrete deterioration rate.
| Train | A/B | C/D | E/F | G/H | Scenarios | Worst case | Average case | Worst case | Average case | Worst case | Average case | Worst case | Average case |
| Built (year) | 1977 | 1982 | 1987 | 1995 | Operated (year) | 1979 | 1984 | 1989 | 1997 | Compressive strength (MPa) | 22.2 | 24.9 | 37.8 | 39.6 | 35.1 | 37.4 | 41.1 | 41.1 | Cover thickness (mm) | 50 | 83 | 32.5 | 65 | 53 | 74 | 44 | 61.7 | Corrosion initiation (year) | 1.82 | 13.91 | 5.73 | 35.56 | 10.25 | 26.13 | 6.99 | 26.13 | Corrosion rate (mm/year) | 0.229 | 0.100 | 0.118 | 0.056 | 0.081 | 0.053 | 0.079 | 0.056 | Remaining capacity at 2013 (%) | 44% | 83% | 77% | 100% | 90% | 100% | 94% | 100% | Remaining capacity in 20 year (%) | 21% | 67% | 59% | 93% | 77% | 92% | 80% | 92% |
|
|