Research Article
Experimental Study of the Effectiveness of Sacrificial Cladding Using Polymeric Foams as Crushable Core with a Simply Supported Steel Beam
Table 4
Experimental results for the investigated sacrificial cladding configurations.
| | (mm) | FP mass (g) | (mm) | (mm) | Std (%) | (ms) | (—) | (m/s) | Eff (%) |
| Without sc | — | — | 104 | 57.57 | 4.51 | 32 | — | — | — |
| PS13-050-FP3 | 50 | 336 | 105 | 57.31 | 4.10 | 34 | 0.95 | 34 | — | PS13-050-FP4 | 50 | 495 | 92.53 | 42.34 | 3.60 | 32 | 0.95 | 21 | 13.57 |
| PS13-100-FP3 | 100 | 336 | 84 | 35.16 | 5.80 | 32.5 | 0.90 | 30 | 23.67 | PS13-100-FP4 | 100 | 495 | 77 | 24.75 | 1.30 | 32.5 | 0.85 | 22 | 31.95 |
| PU30-050-FP1 | 50 | 144 | 98.03 | 54.47 | 3.70 | 33.8 | 0.95 | 68.5 | 7.06 | PU30-050-FP2 | 50 | 188 | 98.13 | 51.59 | 5.70 | 33.7 | 0.90 | 37 | 6.95 | PU30-050-FP3 | 50 | 336 | 88.10 | 38.84 | 2.30 | 32.5 | 0.75 | 32 | 18.82 | PU30-050-FP4 | 50 | 495 | 67.33 | 23.69 | 4.30 | 33.7 | 0.51 | 23 | 43.40 |
| PU30-100-FP1 | 100 | 144 | 74.96 | 33.10 | 4.65 | 32.6 | 0.72 | 68 | 34.37 | PU30-100-FP3 | 100 | 336 | 65.02 | 12.82 | 5.51 | 34.6 | 0.65 | 29.5 | 46.13 | PU30-100-FP4 | 100 | 495 | 59.72 | 12.50 | 7.10 | 32 | 0.30 | 21.5 | 52.40 |
| PU30-150-FP1 | 150 | 144 | 70.12 | 22.49 | 2.40 | 32.55 | 0.48 | 69 | 40.09 |
| PU50-050-FP1 | 50 | 144 | 78.25 | 34.06 | 6.10 | 32.5 | 0.92 | 68.5 | 30.47 | PU50-050-FP3 | 50 | 336 | 62.27 | 21.94 | 3.40 | 32.5 | 0.70 | 31 | 49.38 |
|
|