Research Article
Evaluation of Critical Parameters to Improve Slope Drainage System
Table 1
Proposed partial drainage pipes’ configuration.
| Parameters | Experiments in this study | Simona (2012) | Scale (experiment : real) |
| Nominal diameter, DN (mm) | 25 | 250 | 1 : 10 | Outside diameter, d (mm) | 25 | 250 | 1 : 10 | Thickness of pipe’s wall (mm) | 2.3 | 22.7 | 1 : 9.87 | Pipe’s inside diameter, di (mm) | 20.4 | 204.76 | 1 : 10 | Size of holes, Li (mm) | 4 (diameter of circle) | 80 (rectangular) | — | Number of slots, n | 4 | 3 | — |
|
|