Research Article
Bond Strength between Hybrid Fiber-Reinforced Lightweight Aggregate Concrete Substrate and Self-Compacting Concrete as Topping Layer
Table 4
Pull-off test results.
| Average compressive strength of SCC topping (MPa) | Tensile bond strength of as-placed substrate surface (MPa) | Failure location | Tensile bond strength of grooved substrate surface (MPa) | Failure location |
| 31.30 | 1.05 | Interface | 1.20 | Interface | 0.96 | Interface | 1.18 | Interface | 0.97 | Interface | 1.27 | Interface | 34.51 | 1.26 | Interface | 1.46 | Interface | 1.21 | Interface | 1.50 | Interface | 1.18 | Interface | 1.41 | Interface | 42.99 | 1.39 | Interface | 1.68 | Interface | 1.37 | Interface | 1.63 | Interface | 1.40 | Interface | 1.78 | Interface | 51.66 | 1.69 | Interface | 1.89 | Interface | 1.56 | Interface | 1.95 | Interface | 1.59 | Interface | 2.05 | Interface | 61.85 | 1.89 | Interface | 2.13 | Substrate | 1.91 | Interface | 2.17 | Substrate | 1.83 | Interface | 2.08 | Substrate |
|
|