Research Article

Parameter Analysis on Wind-Induced Vibration of UHV Cross-Rope Suspension Tower-Line

Table 2

The parameter of cross-rope suspension tower-line.

Part nameSpecificationCalculation of sectional area/mm2

ConductorJL/G3A-1000/451045.38 (1043)
Ground wireLBGJ-150-20AC162.877 (148.07)
Guy1 × 37-28.0-1470-B464.95
Suspension-rope1 × 37-28.0-1470-B464.95
Insulator1000
Steel-rope1 × 19-5.0-1470-B14.92