Research Article

Heat Treatment and Ventilation Optimization in a Deep Mine

Table 2

The measured air volume of main roadway before and after transformation of ventilation system.

Ventilation tunnelPreoptimized air volume (m3/s)Optimized air volume (m3/s)Changing of air volume (m3/s)

1118 m pithead inlet air tunnel22.337.0+15.7
Blind shaft entry21.536.3+14.8
640 m level main air tunnel21.135.114.2
640 m level leading to the main return air tunnel18.312.1−6.8
440 m inclined shaft airway5.422.5+17.4
440 m level return air well5.210.2+5.4
440 m level working face0.22.9+2.7
280 m inclined shaft airway06.8+6.8
280 m level return air well06.2+6.2
280 m level working face0.13.0+2.9