Research Article

Heat Treatment and Ventilation Optimization in a Deep Mine

Table 3

Temperature and humidity monitoring data before and after cooling.

Monitoring pointTemperature (°C)Relative humidity (%)
After coolingBefore coolingAfter coolingBefore cooling

A29.232.37992
B29.532.98195
C30.133.58394
D29.933.98697
E29.234.18495
F28.633.78493
G28.133.28092
H27.632.77690