Research Article

A Combined Modal Correlation Criterion for Structural Damage Identification with Noisy Modal Data

Table 3

Beam example: norm values for different damage scenarios and 1 to 4 known modes (noise 10%).

Known modesDamage scenario
1234

1 mode0.2590.5710.6510.518
2 modes0.1190.0590.1100.353
3 modes0.0000.0000.0720.122
4 modes0.0000.0000.0000.222