Research Article
Simulation Analysis on Water’s Micro Seepage Laws under Different Pressure Gradients Using Computed Tomography Method
Table 6
Simulated results of seepage parameters in four models under a low inlet pressure of 4.3 MPa.
| Model | Pmax (MPa) | Pmin (MPa) | Vmax (m·s−1) | Vmin (10−5 m·s−1) | SIN (10−10 m2) | MIN (10−6 kg·s−1) | SOUT (10−10 m2) | MOUT (10−6 kg·s−1) |
| P1 | 4.13 | 0.08 | 97.60 | 10.16 | 12.10 | 5.61 | 8.37 | 5.61 | P2 | 4.33 | 0.11 | 87.08 | 6.38 | 9.29 | 10 | 8.30 | 9.98 | P3 | 4.38 | 0.11 | 81.55 | 4.21 | 13.02 | 9.90 | 8.60 | 9.89 | P4 | 4.32 | 0.11 | 98.70 | 3.28 | 9.60 | 7.13 | 8.53 | 7.13 |
|
|