Research Article
Mechanical Properties of Steel Fiber-Reinforced Magnesium Phosphate Cement Mortar
Table 4
Index of flexural toughness and ductility of MSFRMM.
| ID | Curing time | ASTM C1609 | Flexural toughness, (kN·mm) | Equivalent flexural strength ratio, (%) |
| S/C-0.6 | 7 d | 28.69 | 76.5 | S/C-0.8 | 24.82 | 69.9 | S/C-1.0 | 24.47 | 70.0 | W/C-0.16 | 7 d | 20.70 | 70.7 | W/C-0.18 | 24.82 | 69.9 | W/C-0.20 | 27.27 | 77.8 | MSF-0.4% | 12 h | 15.16 | 63.8 | MSF-0.8% | 21.24 | 74.5 | MSF-1.2% | 21.92 | 72.6 | MSF-1.6% | 21.62 | 70.3 | MSF-0.4% | 1 d | 18.71 | 75.5 | MSF-0.8% | 21.45 | 73.2 | MSF-1.2% | 24.29 | 76.3 | MSF-1.6% | 23.96 | 66.1 | MSF-0.4% | 3 d | 13.01 | 62.6 | MSF-0.8% | 24.30 | 70.9 | MSF-1.2% | 24.51 | 70.8 | MSF-1.6% | 25.52 | 68.9 | MSF-0.4% | 7 d | 18.08 | 73.6 | MSF-0.8% | 24.82 | 69.9 | MSF-1.2% | 26.02 | 72.2 | MSF-1.6% | 30.71 | 65.7 |
|
|