Research Article

Seismic Response Analysis of Fully Base-Isolated Adjacent Buildings with Segregated Foundations

Table 9

Summarized responses of fully BI adjacent buildings considering seismic gaps.

ResponseGap distance (mm)
30170300

Pounding force (kN)2289.811920.701366.15
Dis.(taller building−) top floor (cm)21.2121.3321.14
Dis.(taller building+) top floor (cm)−18.09−16.88−16.88
Acc.(taller building−) (m/s2)−15.14−11.27−7.85
Acc.(taller building+) (m/s2)5.164.1924.192
Base shear(x) (kN)5471.64351.64351.6
Base shear(Y) (kN)424642464246
Base moment(x) (kN·m)41,03730,56730,567
Base moment(Y) (kN·m)102,044102,319102,573
Storey drift ratio0.0007410.0005350.000428
F-D of base isolators(taller building) (kN·mm)119–10145–13147–13
F-D of base isolators(shorter building) (kN·mm)130–1191–791–7

−: negative direction; +: positive direction.