Research Article

Effect of Low-Stress Fatigue on the Off-Crack-Plane Fracture Energy in Engineered Cementitious Composites

Table 4

The test results during the dynamic test.

Stress level, S10.650.590.550.340.260.23

Fatigue cycles110,00010,00010,00010,00010,00010,000
Number of cracks27171311764