Research Article
Examination of Environmental Factors Influencing the Emission Rates of Semivolatile Organic Compounds
Table 6
Test results (air exchange rate = 1.5 h−1).
| Case | Temperature (°C) | Relative humidity (%) | Airborne particles | SVOC adsorption area | DEHP collection volume (ng) | DEHP emission rate (μg/m2h) | 0.5 h after the exp. began | 24 h after the exp. began | 0.5 h after the exp. began | 24 h after the exp. began |
| 1 | 28 | 50 | — | Inner wall of the chamber | 131.9 | 1686.4 | 49.8 | 13.3 | 2 | 40 | 50 | — | Inner wall of the chamber | 184.0 | 5365.0 | 69.4 | 42.2 | 3 | 28 | 40 | — | Inner wall of the chamber | 100.0 | 1293.6 | 37.7 | 10.2 | 4 | 28 | 70 | — | Inner wall of the chamber | 240.0 | 1172.5 | 90.6 | 9.2 | 5 | 28 | 50 | Quartz wool: 170 mg | Inner wall of the chamber + quartz wool | 335.9 | 2733.0 | 126.8 | 20.6 | 6 | 28 | 50 | Quartz wool: 340 mg | Inner wall of the chamber + quartz wool | 671.8 | 3723.0 | 253.5 | 29.1 |
|
|