Research Article

Examination of Environmental Factors Influencing the Emission Rates of Semivolatile Organic Compounds

Table 6

Test results (air exchange rate = 1.5 h−1).

CaseTemperature (°C)Relative humidity (%)Airborne particlesSVOC adsorption areaDEHP collection volume (ng)DEHP emission rate (μg/m2h)
0.5 h after the exp. began24 h after the exp. began0.5 h after the exp. began24 h after the exp. began

12850Inner wall of the chamber131.91686.449.813.3
24050Inner wall of the chamber184.05365.069.442.2
32840Inner wall of the chamber100.01293.637.710.2
42870Inner wall of the chamber240.01172.590.69.2
52850Quartz wool: 170 mgInner wall of the chamber + quartz wool335.92733.0126.820.6
62850Quartz wool: 340 mgInner wall of the chamber + quartz wool671.83723.0253.529.1