Research Article

Examination of Environmental Factors Influencing the Emission Rates of Semivolatile Organic Compounds

Table 7

CFD analysis results (air exchange rate = 1.5 h−1).

Case789

Air exchange rate (h−1)0.81.54.0
Uin (m/s)2.1 × 10−23.9 × 10−25.2 × 10−2
Average airflow in the microchamber (m/s)4.7 × 10−59.9 × 10−51.5 × 10−4
Airflow near the specimen (m/s)3.5 × 10−55.0 × 10−55.0 × 10−5
Mass transfer coefficient (m/h)0.93.57.7
Average age of air in the microchamber0.790.871.78
Coefficient of air change performance1.60.80.1