Research Article

Testing the Key Performance of Mobile Flood Protection System

Table 2

Measured values of steel bar meters of the two installation methods (unit: MPa).

Number of steel bar meterTime of measurementDirect installation methodReserved slot method
Actual measured valueVariation valueActual measured valueVariation value

R1 (Ф14)Before storage4.320.90−2.831.04
Storage to 1.8 m5.22−1.79
R2 (Ф12)Before storage−15.960.49
Storage to 1.8 m−15.47
R3 (Ф12)Before storage14.35−5.7122.93−5.64
Storage to 1.8 m8.6417.29
R4 (Ф16)Before storage3.440.876.251.39
Storage to 1.8 m4.317.64
R5 (Ф16)Before storage22.87−5.926.380.82
Storage to 1.8 m16.957.20