Research Article
Identifying the Impact Factors of the Dynamic Strength of Mudded Intercalations during Cyclic Loading
Table 2
Obtained values of A and B.
| Group number | Confining pressure, σ3 (kPa) | A | B (10−2) |
| 1 | 100 | 6.324 | 0.947 | 200 | 7.736 | 0.817 | 300 | 8.779 | 0.353 |
| 2 | 100 | 6.138 | 3.498 | 200 | 7.175 | 1.174 | 300 | 8.533 | 3.822 |
| 3 | 100 | 9.035 | 50.931 | 200 | 7.441 | 29.820 | 300 | 8.554 | 27.871 |
| 4 | 100 | 6.774 | 1.127 | 200 | 8.899 | 5.376 | 300 | 9.236 | 0.989 |
| 5 | 100 | 6.916 | 1.195 | 200 | 8.332 | 0.807 | 300 | 9.947 | 3.927 |
| 6 | 100 | 6.776 | 4.332 | 200 | 7.869 | 6.066 | 300 | 8.231 | 5.375 |
| 7 | 100 | 6.828 | 0.678 | 200 | 8.660 | 3.690 | 300 | 9.025 | 0.444 |
| 8 | 100 | 7.372 | 4.224 | 200 | 7.474 | 2.838 | 300 | 8.217 | 1.994 |
| 9 | 100 | 5.746 | 8.360 | 200 | 5.588 | 2.914 | 300 | 6.164 | 4.403 |
|
|