Research Article

Experimental Study on High-Cycle Fatigue Behavior of GFRP-Steel Sleeve Composite Cross Arms

Table 2

Summary of test results.

SpecimenTest phenomenonFailure testResidual ultimate bearing capacity (kN)

GZ-1No significant fatigue failure phenomenonAxial compression5,850
GZ-2No significant fatigue failure phenomenonAxial compression5,825
GZ-3No significant fatigue failure phenomenonAxial compression5,891
GZ-4No significant fatigue failure phenomenonAxial compression6,304
GZ-5No significant fatigue failure phenomenonAxial compression5,617
GZ-6No significant fatigue failure phenomenonAxial compression5,566