Research Article

Experimental Study on High-Cycle Fatigue Behavior of GFRP-Steel Sleeve Composite Cross Arms

Table 3

Fatigue life prediction.

SpecimenLoading conditionCyclesParameter, Residual ultimate bearing capacity (kN)Fatigue life prediction

GZ-11500,0000.8805,8507,037,400
GZ-21500,0000.8915,8256,516,700
GZ-32500,0000.9835,8915,643,500
GZ-43500,0000.9326,30424,397,000
GZ-54500,0000.9815,6173,812,200
GZ-65500,0000.9795,5663,590,400
GZ-75500,0000.9415,842.175,721,700