Research Article
A Hierarchy of Architectural Design Elements for Energy Saving of Tower Buildings in Korea Using Green BIM Simulation
Table 5
Changes in energy expenditure per unit area due to ratio of long side to short side and window area ratio (%).
| Scale | 30 × 10 | 20 × 10 | 30 × 20 | 20 × 20 | 20 × 30 | 10 × 20 | 10 × 30 | Average | Ratio of long side to short side | 3 : 1 | 2 : 1 | 1.5 : 1 | 1 : 1 | 1 : 1.5 | 1 : 2 | 1 : 3 |
| 10∼20% | 28.0 | 29.4 | 20.6 | 23.3 | 20.6 | 29.4 | 28.0 | 25.6 | 20∼30% | 21.0 | 21.6 | 16.8 | 18.5 | 16.8 | 21.6 | 21.0 | 19.6 | 30∼40% | 16.5 | 16.8 | 14.0 | 15.1 | 14.0 | 16.8 | 16.5 | 15.7 | 40∼50% | 13.4 | 13.6 | 11.9 | 12.6 | 11.9 | 13.6 | 13.4 | 12.9 | 50∼60% | 11.2 | 11.3 | 10.3 | 10.7 | 10.3 | 11.3 | 11.2 | 10.9 | 60∼70% | 9.6 | 9.6 | 9.0 | 9.3 | 9.0 | 9.6 | 9.6 | 9.4 | 70∼80% | 8.3 | 8.3 | 8.0 | 8.1 | 8.0 | 8.3 | 8.3 | 8.2 | 80∼90% | 7.3 | 7.2 | 7.1 | 7.2 | 7.1 | 7.2 | 7.3 | 7.2 | 10∼90% | 189.2 | 195.5 | 149.9 | 165.5 | 149.8 | 195.4 | 189.0 | 176.3 |
|
|