Research Article

Seismic Performance of a Corroded Reinforce Concrete Frame Structure Using Pushover Method

Table 3

Detailed reinforcement parameters of beams and columns.

Column reinforcement (mm2)Beam reinforcement (mm2)
StoreyBeam numberingUpper reinforcementBottom reinforcement

1–320361256804
4–616081017942