Research Article
Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor
Table 1
Material properties and conditions of the computer model.
| Construction | Description | U-value (W/m2K) |
| Ground/exposed floor | Concrete (180 mm) + insulating material (65 mm) + cultivated sandy soil (40 mm) + polystyrene (65 mm) | 0.4121 | Internal partition/exterior wall | Concrete (200 mm) | 2.4823 | External/ceiling/floor | Concrete (180 mm) + insulating material (20 mm) + cultivated sandy soil (40 mm) + polystyrene (40 mm) | 0.9565 | External glazing | Double glazing: clear float (6 mm) + cavity (12 mm) + clear float (6 mm) | 2.7387 | Glass data: conductivity (1.06 W/mK), transmittance (0.78), outside reflectance (0.07), outside reflectance (0.07), refractive index (1.526) | | Roof | Plaster 95 mm + concrete 200 mm | 1.1400 |
|
|