Research Article

An Analytical Study of Square CFT Columns in Bracing Connection Subjected to Axial Loading

Table 3

The main results of the tests.

SpecimensDescriptionYield load, Fy (kN)Δy (mm)Ultimate load, Fu (kN)Δu (mm)

SJ1-1Gusset plate (12 mm)25003.7829507.10
SJ2-125003.81390011.52
SJ1-2Gusset plate (18 mm)35003.72455012.55
SJ2-235003.78525013.90
SJ1-3Single hole21006.7328509.7
SJ2-321006.78395013.25
SJ1-4Ribs26003.53320010.50
SJ2-426003.55430014.07