Research Article

An Analytical Study of Square CFT Columns in Bracing Connection Subjected to Axial Loading

Table 5

The revised elastic modulus coefficient ce.

SpecimensMode 1 ceMode 2 ceAverage

SJ1-10.320.40.36
SJ2-10.450.430.44
SJ1-20.370.570.47
SJ2-20.380.550.47
SJ1-30.60.70.65
SJ2-30.560.570.57
SJ1-40.930.840.88
SJ2-40.820.940.88