Research Article
Acoustic Emission and Failure Modes for Coal-Rock Structure under Different Loading Rates
Table 1
Loading rate of each sample.
| No. | Loading rate (mm·min−1) | Loading rate (mm·s−1) | Strain rate (s−1) |
| 1 | 0.006 | 1E − 4 | 1E − 6 | 2 | 0.012 | 2E − 4 | 2E − 6 | 3 | 0.03 | 5E − 4 | 5E − 6 | 4 | 0.04 | 7E − 4 | 7E − 6 | 5 | 0.06 | 1E − 3 | 1E − 5 | 6 | 0.12 | 2E − 3 | 2E − 5 |
|
|