Research Article

Theoretical and Experimental Study on the Antisliding Performance of Casting Steel Cable Clamps

Table 3

Specification of specimens.

SpecimenBolt diameter (mm)Number of bolts ()Net length of the bolt (mm)Length of clamp along the cable (mm)Cable cross-sectional diameter  (mm)Metallic cross-sectional area (mm2)Cable tension force (kN)

Φ100-127427641710058944240
Φ100-2
Φ116-1824540011679294277
Φ116-2
Φ127-1836259312795196756
Φ127-2
Φ140-18245400140114676511
Φ140-2