Research Article
Integration of BIM and Energy Consumption Modelling for Manufacturing Prefabricated Components: A Case Study in China
Table 10
Energy consumption data of each equipment for 1 m3 prefabricated column production.
| Equipment | Type | Energy consumption parameters | Operation time (h) | Energy consumption (kJ) |
| Steel bar cutter | GQ50 | 4 kw | 1.5 | 21.6 | Steel bar bender | GW50 | 7 kw | 1 | 25.2 | Bridge crane | LH5-16.5A4 | The fuel consumption per shift is 25.8 kg | 3 | 412658.1 | Steel bar hoop bender | GF25 | 5 kw | 1 | 18 | Forklift truck | CPCD50-AG55 | 86 kw | 0.5 | 154.8 |
|
|