Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars

Table 3

Experimental test results and effect of test parameters on the column axial capacity.

No.G.Specimene/hρ (%)Pmax (kN)Δmax (mm)Mmax (kN·m)% Change (increase or decrease) in column axial capacity
Due to eccentricityRelative to conventional steel barsDue to increase in ρDue to decrease tie spacing

11S12-T90-E0.00.02.09161.551.420.00.0
2S12-T90-E0.50.529713.8126.38−67.60.0
3S12-T90-E1.01.013019.0021.97−85.80.0

42C10-T90-E0.00.01.48553.472.970.00.0
5C10-T90-E0.50.525817.9623.98−69.80.0
6C10-T90-E1.01.011923.6820.67−86.10.0

73C12-T90-E0.00.02.09093.543.220.0−0.86.31.1
8C12-T90-E0.50.526218.0024.37−71.2−11.81.6−0.8
9C12-T90-E1.01.012618.0921.18−86.1−3.15.9−2.3

104C16-T90-E0.00.03.69600.800.770.012.3
11C16-T90-E0.50.529018.3427.11−69.812.6
12C16-T90-E1.01.013720.6223.37−85.715.1

135C12-T140-E0.00.02.08991.301.170.00.0
14C12-T140-E0.50.526413.9823.49−70.60.0
15C12-T140-E1.01.012919.1721.82−85.70.0

166C12-T40-E0.00.02.09251.191.100.02.9
17C12-T40-E0.50.5237.717.2321.92−74.3−10.0
18C12-T40-E1.01.011319.0119.10−87.8−12.4

The negative sign in front of the numbers represent the reduction in strength of the specimen relative to the column that is considered reference for the respective specimens.