The parameters used in and the frequencies measured from the field test.

Number (m) (m)Effective tension (kN)Measured frequency (Hz)

10.1202.51798.3498
20.1232.517196.5556
30.1272.517317.6616
40.1212.51778.3478
50.1242.527220.3568
60.1282.527307.6603
70.1062.527110.2514
80.1092.527196.5550
90.1122.537327.6629
100.1042.53798.3493
110.1082.537210.8585
120.1132.537327.6622
130.0872.54765.6488
140.1612.547196.5547
150.1042.547262.1585
160.1132.547317.6605