Research Article

Stiffness Analysis of Recycled Self-Compacting Concrete-Filled Circular Steel Tubular Columns under Eccentric Compression

Table 7

Comparisons of the deflection values predicted by the proposed equation and test data of the reference.

Specimen IDProposed model (mm)Test data (mm)

CL12-8-100-205.1565.0641.01
CL12-8-100-406.3666.4990.98
CL32-8-100-2014.78313.7941.07
CL32-11-100-2016.66213.9141.19
CL32-14-100-2014.00016.2770.86
CL32-8-50-2013.80013.3451.03
CL32-8-0-2012.57212.7110.99
CL32-8-100-4016.21313.1541.23
CL32-8-50-4016.22512.1761.31
CL32-8-0-4014.31112.0341.18
CL48-8-100-2022.21018.4091.20
CL48-8-100-4019.00019.4120.98
Mean square error0.133
Average value1.086

Note. An example of the test specimen identification system is as follows: CL12-8-100-0, where CL accounts for a composite column with the aggregate, the digit number “12” is the length-diameter ratio (), the digit “8” defines the nominal ratio of 8%, the digit “100” represents the RCA replacement ratio of 100%, and the last one “0” denotes eccentricity of load with 0 mm.