Experimental Assessment of RC Beam-Column Connections with Internal and External Strengthening Techniques

Table 1

Characteristics of column-beam joint specimens.

Specimen IDColumn characteristicsBeam characteristicsJoint reinforcementRetrofitting
DimensionLongitudinal barsStirrupsρl (%)ρs (%)DimensionLongitudinal barsStirrupsρl (%)ρs (%)StirrupsIn jointIn member

Target300 × 3004Ø20Ø8/1001.130.33300 × 3602Ø20 (top)Ø8/1001.130.332Ø10 (both directions)
3Ø20 (bottom)1.69
Control300 × 3004Ø20Ø8/1001.130.33300 × 3602Ø20 (top)Ø8/1001.130.33
3Ø20 (bottom)1.69
Sample 1300 × 3004Ø20Ø8/3001.130.11300 × 3602Ø20 (top)Ø8/3001.130.11Externally retrofitted by CFRP
3Ø20 (bottom)1.69
Sample 2300 × 3004Ø20Ø8/3001.130.11300 × 3602Ø20 (top)Ø8/3001.130.11Internally retrofitted by 4Ø12 diagonal bars
3Ø20 (bottom)1.69
Sample 3300 × 3004Ø20Ø8/3001.130.11300 × 3602Ø20 (top)Ø8/3001.130.11Internally retrofitted by 4Ø12 diagonal barsExternally retrofitted by CFRP
3Ø20 (bottom)1.69
Sample 4300 × 3004Ø20Ø8/3001.130.11300 × 3602Ø20 (top)Ø8/3001.130.11Externally retrofitted by CFRPExternally retrofitted by CFRP
3Ø20 (bottom)1.69