Research Article

Analysis of Vibration Response Law of Multistory Building under Tunnel Blasting Loads

Table 2

Raw monitoring data.

FloorMVxmaxVymaxVzmaxVmaxFxFyFzDxDyDz

First10.4490.4791.0361.22733.665.468.51.2601.2411.423
20.3590.5170.8761.07973.568.180.61.2611.2531.453
30.3930.5561.1091.30145.555.278.11.2191.2451.666
40.4150.4270.8681.30162.072.075.01.2301.1831.326

Second10.4680.5701.0781.39646.359.580.61.2071.1751.321
20.4400.5461.0631.27450.058.173.51.2001.2031.240
30.4820.5951.2311.36453.261.061.01.1811.1431.412
40.4480.5100.9351.47151.055.650.01.2001.0711.252

Third10.5160.7521.3541.55650.041.744.91.1411.1531.213
20.5400.6991.3371.60250.539.246.31.1701.1201.193
30.5450.6191.4291.63042.940.753.81.0981.1281.274
40.6260.5551.4041.63026.634.853.21.1091.0671.142

Fourth10.4230.6271.0611.30319.821.727.21.0981.0961.189
20.3980.5120.8651.08116.125.026.31.1601.0611.040
30.4460.5540.8371.09925.620.826.31.0571.0571.121
40.4990.5300.8921.09920.021.730.31.1031.0171.059

Note. M represents the number of monitoring; Vxmax, Vymax, Vzmax, and V represent the peak particle velocity (cm/s) in x, y, z, and co-direction, respectively; Fx, Fy, and Fz represent dominant frequency (Hz) in x, y, and z directions, respectively; Dx, Dy, and Dz represent duration (s) of the vibration in x, y, and z directions, respectively.