Research Article
Test and Numerical Study on Monotonic Behavior of Complex CFT Column Joints
Table 3
Design load case LS1 of testing joints.
| Joints | Member | N (kN) | V1 (kN) | V2 (kN) | M1 (kN·m) | M2 (kN·m) |
| A1 | 1 | 3064 | 462 | — | 220 | 252 | 2 | 1324 | — | — | — | — | 3 | 772 | — | — | 70 | — | 7 | 620 | — | — | — | — | 8 | 1232 | — | — | 106 | — |
| A2 | 1 | 1585 | 177 | 325 | 38 | 570 | 4 | 1825 | — | — | — | — | 5 | 865 | 130 | — | 160 | — | 6 | 120 | — | — | 42 | — |
| B1 | 1 | 3375 | — | — | — | — | 2 | 3062 | — | — | — | — | 5 | 504 | — | — | — | — |
|
|