Research Article
Test and Numerical Study on Monotonic Behavior of Complex CFT Column Joints
Table 7
Support reaction force calculated under different boundary types.
| Member number | Design load value (kN) | Type 1 (kN) | Type 2 (kN) | Type 3 (kN) | Type 4 (kN) |
| 3 | 772 | — | 321 | — | 162 | 4 | 3774 | 3684 | 3620 | 3280 | 3458 | 5 | 654 | 636 | 568 | 780 | 520 | 6 | 976 | 831 | — | 656 | 125 | 7 | 620 | — | — | 12 | — | 9 | 554 | 445 | 720 | 582 | 580 |
|
|