Research Article

A Simplified Calculation Method of Length Adjustment of Datum Strand for the Main Cable with Small Sag

Table 1

Comparison of the calculation results of the unstressed length and cable length adjustment.

ItemTheory of catenaryQuasi-catenary theoryPerfect solution of parabola theoryTraditional simplified formulaThe improved simplified formula IThe improved simplified formula II

Unstressed cable length (m)237.56707237.56706237.57255238.12012237.55485/
Cable length error (m)0−0.000010.005480.55305−0.01222/
Cable length adjustment (mm)33.6035.9534.427913.2134.427833.9906
Relative error of adjustment0%7.0%2.5%−60.7%2.5%1.2%