Research Article

Optimization of the Mixture Design of Low-CO2 High-Strength Concrete Containing Silica Fume

Table 5

Performance of low-CO2 high-strength concrete.

Low-CO2 concretefc (MPa)Slump (mm)CO2 emission (kg/m3)Cost (NT dollar/m3)Water/binderSilica fume/binderSand ratioSp/binder

Mix1-95 MPa95.00202.79550.212271.930.260.050.390.02
Mix2-100 MPa100.00194.40550.652312.920.250.050.390.02
Mix3-105 MPa105.00188.14554.022580.690.240.090.390.03
Mix4-110 MPa110.00184.89561.503169.040.240.190.390.03
Mix5-115 MPa115.00182.74594.223668.590.230.250.390.04