Research Article

Optimization of the Mixture Design of Low-CO2 High-Strength Concrete Containing Silica Fume

Table 8

Performance of low-cost high-strength concrete.

Low-cost concretefc (MPa)Slump (mm)Cost (NT dollar/m3)CO2 emission (kg/m3)Water/binderSilica fume/binderSand ratioSp/binder

Mix6-95 MPa95.00202.792271.93550.210.260.050.390.02
Mix7-100 MPa100.00194.402312.92550.650.250.050.390.02
Mix8-105 MPa105.00189.202445.90577.360.230.050.390.03
Mix9-110 MPa110.00188.502740.48653.020.210.050.390.03
Mix10-115 MPa115.00186.613261.80706.800.190.100.390.03