Research Article

Thermal Analyses and Responses of Bridge Deck Hydronic Snow Melting System

Table 4

Maximum principle stress extreme values of HSMP under ambient temperature loads (pipe spacing of 15 cm).

LayersDepth (cm)Maximum principle stress (MPa)
MinMax

AL70.3930.431
90.3970.407
110.3970.404

CL72.0122.782
92.0322.743
112.0432.734

Pipe715.74128.512
916.12327.632
1116.22427.714