Research Article

Thermal Analyses and Responses of Bridge Deck Hydronic Snow Melting System

Table 5

Maximum principle stress extreme values of HSMP under ambient temperature loads (pipe embedded depth of 7 cm).

LayersSpacing (cm)Maximum principle stress (MPa)
MinMax

AL100.3920.424
150.3930.431
200.3930.434

CL102.0112.713
152.0122.782
202.0122.791

Pipe1015.82127.844
1515.74128.521
2015.69128.712