Comparison of load at various stages.
| ā | CFCJ1 | CFCJ2 | CFCJ3 |
| (kN) | 180 | 160 | 140 | (mm) | 8.2 | 10.3 | 10.8 | (kN) | 380 | 342 | 323.6 | (mm) | 16.1 | 18.67 | 19.63 | (kN) | 433 | 384 | 371.6 | (mm) | 54.3 | 45.8 | 56.2 | (kN) | 396 | 322 | 214.6 | (mm) | 67.6 | 68.1 | 72.2 |
|
|