Calculation results of bond strength.
| Label | Lb (mm) | d (mm) | ρ (%) | Ab (×103 mm2) | Sbu (mm) | τu (MPa) | Fb,u (kN) | Fb,r (kN) |
| S-1 | 400 | 400 | 4.8 | 160 | 0.20 | 1.89 | 302.8 | 190.8 | T-1 and T-2 | 150 | 100 | 1.1 | 36 | 0.07 | 2.29 | 82.6 | 52.0 |
|
|