Research Article
Mechanical Properties of Glued-Laminated Timber with Different Assembly Patterns
| No. | Mu (kNm) | M300 (kNm) | α = M300-mixed/M300-uniform | β = Mu/M300 |
| TCT-21(1) | 48.03 | 21.82 | — | 2.20 | TCT-21(2) | 46.26 | 21.36 | — | 2.17 | TCT-21(3) | 45.18 | 20.76 | — | 2.18 | TCYF-21(1) | 64.85 | 26.65 | 1.22 | 2.43 | TCYF-21(2) | 62.45 | 24.78 | 1.16 | 2.52 | TCYF-21(3) | 61.00 | 23.66 | 1.14 | 2.58 | TCYD-21(1) | 72.05 | 32.36 | 1.48 | 2.23 | TCYD-21(2) | 69.39 | 29.67 | 1.39 | 2.34 | TCYD-21(3) | 67.79 | 28.26 | 1.36 | 2.40 | TCT-24(1) | 61.23 | 35.89 | — | 1.71 | TCT-24(2) | 59.46 | 34.56 | — | 1.72 | TCT-24(3) | 58.54 | 33.36 | — | 1.75 | TCYF-24(1) | 81.23 | 40.86 | 1.14 | 1.99 | TCYF-24(2) | 80.16 | 39.55 | 1.14 | 2.02 | TCYF-24(3) | 77.84 | 37.96 | 1.14 | 2.05 | TCYD-24(1) | 90.61 | 48.92 | 1.36 | 1.85 | TCYD-24(2) | 89.07 | 47.58 | 1.38 | 1.87 | TCYD-24(3) | 86.13 | 45.97 | 1.38 | 1.87 |
|
|