Research Article

Dynamic Splitting Tensile Properties and Failure Mechanism of Layered Slate

Table 2

Summary of the static tensile test results on samples.

Specimen no.The inclination angles β (°)Diameter (mm)Thickness (mm)Static failure load (MPa)Average failure load (MPa)

SA-1049.5823.772.362.75
SA-248.6525.563.53
SA-348.6125.192.36

SE-11549.5626.703.854.02
SE-248.6225.644.42
SE-348.7725.223.79

SF-13049.5623.722.633.87
SF-248.6726.074.51
SF-348.6525.894.48

SB-14549.4625.695.495.12
SB-248.7024.034.56
SB-348.6125.455.32

SC-16049.5526.163.714.13
SC-248.6325.495.22
SC-348.6425.804.45
SC-448.7226.233.15

SG-17549.7427.667.948.14
SG-248.725.869.04
SG-348.6125.977.45

SD-19049.5926.908.448.92
SD-248.6125.339.13
SD-348.6825.509.20