Research Article

Damage Assessment of an SRC Frame-Core Tube Structure under the Action of a Main Aftershock Sequence

Table 14

Vulnerability index of the structure under the main shock/main aftershock.

Sa(T1, 5%)Vulnerability index (%)
VILVIMVIU
Main shockMain aftershockMain shockMain aftershockMain shockMain aftershock

0.000.000.005.005.0010.0010.00
0.053.8911.7310.2920.1716.7028.60
0.1015.3528.2824.5139.1933.6650.09
0.2037.0050.4448.4861.9859.9673.52
0.5069.2075.1779.3284.4789.4393.77
1.0081.8083.0289.9790.9598.1398.87
1.5084.1584.4391.8492.0699.5399.69
2.0084.7384.8092.2992.3599.8599.89
2.5084.9084.9292.4292.4499.9599.96
3.0084.9684.9692.4792.4799.9899.98
3.5084.9884.9892.4992.4999.9999.99
4.0084.9984.9992.4992.49100.00100.00