Research Article

A New Method to Calculate Additional Damping Ratio considering the Effect of Excitation Frequency

Table 1

Fitting coefficients of the polynomial for different ω values.

ω (rad/s)Fitting coefficients
b 1b 2b 3b 4

20.23–0.420.300.01
40.34–0.860.800.01
5.390.40–0.890.840.04
81.11–2.391.810.04
101.76–3.702.660.07
121.84–3.993.040.08
141.19–3.133.020.02
160.50–2.002.730.00
180.14–1.282.440.01
20–0.05–0.862.270.03